| OUTPUT |
| Output Volt Amp Capacity (VA) |
1000 |
| Output Watt Capacity (watts) |
500 |
| Nominal Output Voltage(s) Supported |
115V; 120V |
| Frequency compatibility |
60 Hz |
| Output voltage regulation (Battery mode) |
115V (+/- 5%) |
| Built-in UPS output receptacles |
8 5-15R outlet(s) |
| Surge suppression only outlets |
4 UPS outlets, 4 surge-only outlets |
| Output AC waveform (AC mode) |
Sine wave |
| Output AC waveform (battery mode) |
PWM sine wave |
| INPUT |
| Rated input current (at maximum load) |
12A |
| Nominal Input Voltage(s) Supported |
120V AC |
| UPS input connection type |
5-15P |
| UPS Input cord length (ft.) |
6 |
| UPS Input cord length (m) |
1.8 |
| Recommended Electrical Service |
15A 120V |
| BATTERY |
| Full load runtime (minutes) |
3 min. (500w) |
| Half load runtime (minutes) |
10 min. (250w) |
| DC system voltage (VDC) |
12 |
| Battery recharge rate (included batteries) |
Less than 20 hours from 10% to 90% |
| Replacement battery cartridge (internal UPS battery replacement) |
RBC51 |
| Battery Access |
Battery access door |
| Battery replacement description |
Hot-swappable, user replaceable batteries |
| VOLTAGE REGULATION |
| Voltage regulation description |
Automatic voltage regulation (AVR) maintains line power operation with input
voltage as low as 89 |
| Undervoltage correction |
Input voltages between 89 and 104 are boosted by 14% |
| LEDS ALARMS & SWITCHES |
| LED Indicators |
Front panel LCD display |
| Front panel LCD display |
Backlighted LCD screen indicates input voltage, 5-bar battery charge level,
overload, AVR, on battery and replace battery status; LCD screen rotates for
rack/tower viewing |
| Alarms |
Audible alarm indicates power-failure, low-battery and overload status;
alarm can be disabled using PowerAlert software |
| Alarm cancel operation |
Power-fail alarm can be silenced using alarm-cancel switch; once silenced,
alarm will re-sound to indicate low-battery status |
| Switches |
2 Switches control off/on power status and alarm-cancel/self-test operation;
dimmer switch controls LCD brightness |
| SURGE / NOISE SUPPRESSION |
| UPS AC suppression joule rating |
1038 |
| UPS AC suppression response time |
Instantaneous |
| UPS Dataline suppression |
1 line TEL/DSL (1 in / 1 out); Coax jacks (1 set) |
| EMI / RFI AC noise suppression |
Yes |
| PHYSICAL |
| Installation form factors supported with included accessories |
Tower |
| Primary form factor |
Tower |
| UPS / Power Module dimensions in primary form factor (height x width x depth
/ inches) |
12 x 3.7 x 7.2 |
| UPS / Power Module dimensions in primary form factor (height x width x depth
/ cm) |
30.5 x 9.4 x 18.3 |
| Secondary form factor |
Horizontal desktop placement |
| Installed whole system dimensions in secondary form factor (height x width x
depth / inches) |
3.7 x 12 x 7.2 |
| UPS dimensions in secondary form factor (height x width x depth / cm) |
9.4 x 30.5 x 18.3 |
| UPS / Power Module weight (lbs) |
15.5 |
| UPS / Power Module weight (kg) |
7 |
| UPS Shipping dimensions (height x width x depth / inches) |
10.4 x 15.6 x 4.8 |
| UPS Shipping dimensions (height x width x depth / cm) |
26.5 x 39.5 x 12.3 |
| Shipping weight (lbs) |
15.8 |
| Shipping weight (kg) |
7.2 |
| UPS housing material |
ABS |
| ENVIRONMENTAL |
| Operating Temperature Range |
+32 to +104 degrees Fahrenheit / 0 to +40 degrees Celsius |
| Storage Temperature Range |
+5 to +122 degrees Fahrenheit / -15 to +50 degrees Celsius |
| Relative Humidity |
0 to 95%, non-condensing |
| AC mode BTU / hr. (full load) |
31 |
| COMMUNICATIONS |
| Communications interface |
USB (HID enabled) |
| PowerAlert software |
Free download from www.tripplite.com |
| Communications cable |
USB cable included |
| |
|